Skip to content
Public & tradeWholesale prices, bought direct — open to the public and the trade.Open a trade account
Allow EnergySolar components and design tools
Quick order
Sign in

Brand: SolarEdge

Product code: AEI-00743

66.6kW Synergy Manager SWITCH with DC Switch, MC4, DC SPD

  • 66.6 kW

Synergy Manager for the SolarEdge SE66.6K three-phase Synergy inverter, with DC safety switch, MC4 connections and Type II DC surge protection.

£1,457.47 inc. VAT

£1,214.56 exc. VAT

Out of stock

This is the Synergy Manager for SolarEdge's SE66.6K three-phase inverter with Synergy technology, for 400V grids in Europe. A complete SE66.6K inverter is made up of one Synergy Manager and two Synergy Units, which are separate items; together they are rated at 66,600W AC output, with a DC operating range of 680 to 1000V. This is the version with the DC safety switch, MC4 DC connections and DC surge protection: Type II DC surge protection is integrated and field replaceable, and an AC surge protection kit is sold separately. The inverter's DC input is 8 MC4 pairs, 4 per Synergy Unit. The Synergy Manager measures 360 x 560 x 295mm, weighs 18kg and is rated IP65. The inverter is commissioned with the SolarEdge SetApp, and its datasheet lists the UK G99 Type A+B grid standard.

Specifications

Synergy Manager

Dimensions, Synergy Manager (H x W x D)360 x 560 x 295 mm
Weight, Synergy Manager18 kg
DC disconnect switchOptional (by part number)
DC surge protectionType II, field replaceable, integrated
AC surge protectionType II, field replaceable, optional (AC SPD kit for Synergy Manager, P/N SE-AC-SPD-SM, purchased separately)
RS485 surge protection (ports 1 + 2)Type II, field replaceable, integrated
DC fuses (single pole)Optional, 25 A / 30 A
DC connectionMC4 or gland, depending on part number; only MC4 connectors made by Staubli are approved

SE66.6K inverter (Synergy Manager + Synergy Units)

Number of Synergy Units per inverter2
Rated AC active output power66,600 W
Maximum AC apparent output power66,600 VA
AC output voltage, line to line / line to neutral (nominal)380 / 220; 400 / 230 V AC
AC output voltage, line to line range / line to neutral range304 - 437 / 176 - 253; 320 - 460 / 184 - 264.5 V AC
AC frequency50/60 ± 5% Hz
Maximum continuous output current (per phase)96.5 A AC
AC output line connections3W + PE, 4W + PE
Supported gridsWYE: TN-C, TN-S, TN-C-S, TT, IT; Delta: IT
Maximum residual current injection200 mA
Total harmonic distortion≤ 3%
Power factor range± 0.2 to 1
Maximum DC power (module STC), inverter / per Synergy Unit116,550 / 58,275 W
Maximum input voltage DC+ to DC-1000 V DC
Operating voltage range680 - 1000 V DC
Maximum input current2 x 48.25 A DC
Ground-fault isolation detection167 kΩ sensitivity per Synergy Unit
Maximum inverter efficiency98.3%
European weighted efficiency98%
Night-time power consumption< 8 W
DC input, inverter / per Synergy Unit (MC4 version)8 / 4 MC4 pairs
Communication interfaces2 x RS485, Ethernet, Wi-Fi (optional), Cellular (optional)
Inverter commissioningSetApp mobile application, using the built-in Wi-Fi access point for local connection
Smart energy managementExport limitation
Arc fault protectionBuilt-in, user configurable (according to UL 1699B)
PID rectifierNight-time, built-in
SafetyIEC-62109-1, IEC-62109-2, AS3100
Grid connection standardsEN 50549-1, EN 50549-2, VDE-AR-N 4105, VDE-AR-N 4110, VDE V 0126-1-1, CEI 0-21, CEI 0-16, TOR Erzeuger Typ A+B, G99 Type A+B, G99 (NI) Type A+B, VFR 2019
EmissionsIEC-61000-6-2, IEC-61000-6-3 Class A, IEC-61000-3-11, IEC-61000-3-12
RoHSYes
Operating temperature range-40 to +60 °C
Noise< 67 dBA
Protection ratingIP65, outdoor and indoor
MountingBrackets provided

General

Rated output66.6 kW

Documents and datasheets

Datasheets

  • SolarEdge Synergy Manager for the SE66.6K Three Phase Inverter with Synergy Technology, for Europe (DC safety switch, MC4, DC SPD) — Datasheet

    PDF · 844 kB

    Download

Customer reviews

No reviews yet.

Be the first to tell other shoppers what you think.